TO PROGRAM
SYSTEM
STATUS & RESTORE
REPORT CODES
(*60-*75)
With a 3+1 or 4+1 Standard Format: Enter a code in the first digit box: 1-9, 0, B, C,
D, E, or F. Enter "#+10" for 0, "#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15"
for F.
AO" (not "#+10") in the first digit box will disable a report.
A "0" (not "#+10") in the second digit box (if any) will result in automatic advance to the
next field when programming.
With an Expanded or 4+2 Format:
Enter codes in both boxes (1st and 2nd digits)
for 1-9, 0, or B-F, as described above.
A"0" (not "#+10") in the second box will eliminate the expanded message for that report.
A "0" (not "#+10") in both boxes will disable the report.
With Ademco
Contact ID Reporting: Enter any digit (other than "0") in the first box,
to enable zone to report This is an "enabling" code only and is disregarded in the actual
reporting to the central office. Entries in the second boxes will be ignored.
A"0" (not "#+10") in the first box will disable the report.
See Examples on programming form.
SYSTEM
STATUS
*60
TROUBLE
REPORT
CODE
(See box above.)
REPORT CODES
+61
BYPASS REPORT CODE (See box above.)
("60-"68)
«62
AC LOSS REPORT CODE (See box above.)
*63
LOW
BAT REPORT
CODE
(See box above.)
*64
TEST
REPORT
CODE
(See box above.)
*65
OPEN/EXIT
ALARM
REPORT
CODE,
ist DIGITS
Open Report Code : To enable, enter a code (or 0 to disable) in the
left-hand box (see box above *60).
For expanded or 4+2 reporting, 2nd digit = User #.
Exit Alarm Report Code: To enable, enter a code (or 0 to disable) in
the right-hand box (see box above *60). If enabled:
ANY ALARM FROM AN EXIT OR INTERIOR ZONE OCCURRING WITHIN TWO
MINUTES AFTER THE END OF THE EXIT DELAY will send a special message
indicating exit alarm to the central station, and a zone indication and "Exit Alarm"
or "EA" is displayed on the console.
IF AN EXIT OR INTERIOR ZONE CONTAINS A FAULT AS THE EXIT DELAY
ENDS, the local bell and console sound continuously.
a) /f the subscriber then disarms the system before the ensuing ENTRY delay
ends, no message
is transmitted to the central station, but a zone indication
and "Canceled Alarm" or "CA" is displayed on the console.
b) if the system is not disarmed before that entry delay ends, a special message
indicating Exit Alarm is sent to the central station and a zone indication and
"Exit Alarm" or "EA" is displayed on the console.
For
expanded
or 4+2 reporting, a 2nd digit is sent, and is the same as the
2nd digit of the zone alarm report code programmed in field *56.
For Contact ID reporting, Event code 374 and the zone number is sent.
There is no restore message for Exit Alarm report.
For expanded or 4+2 reporting, 2nd digit for each = User # .
*67
RF XMTR.
LOW
BATTERY
REPORT
CODE
(See box above.)
*68
CANCEL
REPORT
CODE
(See box above.)
(*69-*75)
or:
1 for yes (report after ail zones restored).
Note: "1" not applicable to Contact ID reporting.
*70
ALARM
RESTORE
REPORT
CODE,
1ST
DIGIT
For
expanded
or 4+2 reporting. a 2nd digit is sent, and is the same as the
2nd digit of the zone alarm report code programmed in field *56.
*71
TROUBLE
RESTORE
REPORT
CODE
(See box above.)
*72
BYPASS
RESTORE
REPORT
CODE
(See box above.)
*73
AC RESTORE
REPORT
CODE
(See box above.)
*74
LOW
BAT RESTORE
REPORT
CODE
(See box above.)
—23-