PROGRAMMING
DATA FIELDS
THE CENTERFOLD PROGRAMMING FORM CAN BE USED TO RECORD THE DATA FOR THIS INSTALLATION
SYSTEM
SETUP
(*20-*27)
ZONE SOUNDS AND
TIMING
(*28-*39)
*20
*21
*22
*23
*24
*25
*26
*27
*28
*29
*30
*38
*39
MASTER
CODE
Enter 4 digits, 0-9 (entry of all 4 is mandatory).
Use of a "9" in the last position inhibits the duress code feature.
QUICK
ARM
ENABLE
if enabled, [#] key can be used instead of security code when arming .
Code is always required when disarming.
Enter 0 for disabled or 1 for enabled.
RF
SYSTEM
TYPE
Select the RF system (receiver) type being used.
0 = none; 1 = 5700 (4281); 2 = 5800 (5881)
FORCED
BYPASS
FUNCTION
All zones that are bypassed by this function will be displayed after the
bypass is initiated.
0 = No forced bypass.
1 = Allows quick bypass of all open zones.
RF RECEIVER
HOUSE
1D CODE
MUST enter for 5700 system's 4281 type receiver, or 5800 system's
5827 Wireless Keypad or 5827BD Bidirectional Console.
Enter 01-31 House iD.
WIRED
EXPANSION/OUTPUT
RELAY
USED
Select expansion/relay module being used.
0 =none; 1 = 4219; 2 = 4229; 3 = 4204
VOICE
MODULE
ACCESS
CODE
Supports the 4285 Voice Module on the console lines
(the 4285 has a permanent device address of 4).
To enable, enter two digits. 1st digit: 1-9
2nd digit: '*' (enter #+11) or '#' (enter #+12)
To disable, enter 0 in either position.
OUTPUT
TO
LONG
RANGE
RADIO
(e.g., No. 7720ECP)
Enter 0 for no or 1 for yes.
If yes is selected, any dialer report programmed to report to the PRIMARY
phone number (in field *47) will be sent, as well, via long range radio. All
dialer and long range radio reports will be in Contact ID format (regardless
of the selection made in field *46).
Note: The Radio should be programmed for a device address of 3
on the console lines.
Full Trouble and Restore messages are sent.
SINGLE
ALARM
SOUNDING
PER ZONE
(per armed period)
Affects external sounder only, if yes is selected.
Enter 0 for no or 1 for yes.
FIRE
SOUNDER
TIMEOUT
0 = Fire sounder times out at end of bell timeout period (field *30).
1 = Fire sounder continues until silenced manually.
ALARM
BELL
TIMEOUT
External sounder will shut off after time allotted. Enter 1 digit.
0 = No timeout
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
ENTRY
DELAY
System will wait the time allotted before sounding alarm upon entering.
(EXIT delay = Entry delay plus 15 seconds)
0=Osec, 1 = 20 sec, 2 = 30 sec, 3 = 45 sec, 4 = 60 sec, 5 = 90 Sec.
AUDIBLE
EXIT
WARNING
When arming AWAY or MAXIMUM, console sounds slow beeps during exit
time, turning into fast beeps during last 5 seconds.
Enter 0 for no or 1 for yes.
-18-