General information
You must assign a zone type to each zone, which will then define the way in
which the systemwill respond to faults in that zone. Zone types are defined
below.
Type 00
Zone Not Used
~
01
En&y/Exit Burglary #1
we
02
Entry/Exit Burglary W
Type
03
Perimeter Burglary
Type04
Interior, Follower
Type
05
Trouble by Day/
Alarm by Night
Progmuna zone with this zone @pe if the zone is not used.
This zone type providesexit and entry delays whenever the zone is faulted if
the controlis armed in the Away or Stay modes.When the panel is armed in
the Instant or Maximum modes,no entry delay is provided. Entry delay #1 is
programmable,but Exit delay is automaticallyset as follows:
Exit Delay = Entry Delay (that has been programmed) +40 seconds.
Exit delay begins whenever the control is armed, regardless of the arming
mode selected.This zone type is usually assigned to sensors or contactson
doorsthrough which primary en~
and exit will take place.
This zone type providesa secondaryentry delay whenever the zone is faulted
if the panel is armed in the Away and Stay modes. When the panel is armed
in the Instant or Mazimum modes, no entry delay is provided. Enlz-y and Exit
delays#2 are automaticallyset as follows:
Entry delay #2= programmed Entry delay #1 + 30 seconds.
Ezit delay #2 = programmed Entry delay #1 + 40 seconds.
Exit delay #2 beginswhenever the controlis anneal, regardless of the arming
mode selected.
This zone type is usually assigned to sensors or contacts on doors through
which secondaryentry and ezit will take place, and where more time might
be neededto get ta end from the keypad (typically used for a garage, loading
dock,or basementdoor).
This zone type gives an instant alarm if the zone is faulted when the panel is
armed in the Away, Stay, Instant or Maximum modes. This zone type is
usually assignedto all sensorsor contactson exterior doors and windows.
This zone type gives a delayed alarm (using the programmed Entry/Exit
time) if the Entry/Exit zone is faulted first. Otherwise this zone lype gives an
instant alarm. This zone type is active when the panel is armed in the Away
and Maximum modes.This zone me
is bypassed automatically
when
the panel is armed in the Stay or Instant
modes. This zone type is
usually assignedto a zone covering an area such as a foyer, lobby, or hallway
through which one must pazs upon entry (After faukiug the entry/exit zoneto
reachthe keypad to disarm the system.)
Sincethis zone type is designed to provide an instant slain if the enh-y/ezit
zone is not violated first, it will protectan area in the event an intruder hides
on the premises prior to the system being armed, or gains accessto the
premisesthrough an unprotectedarea.
This zone type will give an instant alarm if faulted when armed in the Away,
Stay, Instant or Msximum (night) modes. During the disarmed state (day),
the system will provide a latched tiouble sounding from the keypad (and a
central station report, if desired). This zone type is usually assigned to a zone
which contains a foil-protected door or window (such as in a store), or to a
zone covering a "sensitive"area such as a stockroom, drug supply room, etc.
This zone type can also be used on a sensor or contact in an area where
immediate notificationof an entry is desired.