ADEMCO Via 30+ Installation Instructions Manual page 22

Table of Contents

Advertisement

20 Learn S/N ?
O=No
1=Yes
0
TRANSMIT NOW
TYPICAL
DISPLAY
Zn ZT-—RC
Inv
L
20 03- 3C
RF:
2
Accepted Input (Loop) Number T
Program Alpha?
O=No
1=Yes
0
Enter Zn Num.
(00=Quit)
00
20 Zone Type
Not Used
00
20 Delete Zone?
1=Yes
O=No
Learning
RF Input (L): Applicable
to a 5800 system
only.
Note:
Where a "Yes—No" is asked by the console, pressing the
[>*] or [0] for No is equivalent.
This request will be to learn the transmitter input's ID code. (The ID codes
can be learned here or via field *83.)
If "yes" is selected, open and close (or close and open), or press and re-
lease the particular input to the transmitter twice. After the first time, a
single short beep will occur. After the second time, two short beeps will
mean that the control has accepted that transmitter into the system. Be-
cause of the characteristics of the receiver, allow about 8 seconds be-
tween transmissions from button units (e.g., 5802, 5802CP, 5803). If a
long beep occurs, it means that the particular transmitter input has
previously been registered in the system.
The display will revert to the summary line, with the accepted input (loop)
number under the "L" in the display.
Mark the zone number on the transmitter.
If all is okay, press [>*].
Custom
Alpha
Editing:
For all zone types, the next request is to
enter alpha descriptors for the zones. The entry may be done now (enter
1) or may be done at a later time via field *82 (enter 0).
See the ALPHA DESCRIPTION ENTRIES section on page 29.
When all entries to be made for the zone at this time are complete, the
next
zone
number
can
be entered
for programming,
or zone
programming
can
be ended
by entering
[0][0] as the next "zone
Notes:
e
When using a 5801, the Input (Loop) "4" button should always be used and
learned by the system.
e
In field *56, at the summary line for each zone, the entered values can be
checked. If it is desired to change anything, press [#] to move to the previous
entry. Press [#] a number of times to move to earlier entries. Press [%] to move
to later entries again.
«
Zone entries can be reviewed by pressing [#][5][6]. Changes cannot be made
here, so this is safer for review. Enter the first zone number to be viewed and
press [#]. To view each zone, press [#] and the zone number will advance to
the next programmed zone. When the end of the list is reached, press [0]{0] to
exit. This method of exiting may also be done at any time during the review.
To either temporarily or permanently remove a zone from the system, go into
programming mode and press [*][5][6]. Enter the zone number and press [*].
At the Zone Type prompt, enter [0][0] and [%]. This sets the type of the zone
to Not Used. The next prompt will be "Delete Zone?". "Yes" will permanently
remove the zone from the system while "No" will disable it but retain all data ex-
cept the original zone type.You can then go back to this zone later and put
back an active Zone Type to re-enable it.
-22—