Power-Up Procedure - ADEMCO Via 30+ Installation Instructions Manual

Hide thumbs Also See for Via 30+:
Table of Contents

Advertisement

Power-up
Procedure
Make sure that the total current to be drawn from the Alarm Output terminals
(3 & 4) and Auxiliary Power Output terminals (4 & 5) does not exceed the
values indicated in the SPECIFICATIONS section and on the SUMMARY OF
CONNECTIONS diagram.
. Wire the transformer to the panel (before connecting the battery) as shown
on the SUMMARY
OF CONNECTIONS
diagram. Do not plug in at this
time.
Connect all loops, devices, consoles, etc. to the panel.
Plug the transformer into a 24 hour, uninterrupted AC outlet. After some ini-
tial displays (see page 17) and approximately one minute, the green POWER
or READY LED on the console(s) should be lit and the consoles should dis-
play "READY" (Fixed Word consoles) or "DISARMED
READY TO ARM"
(Alpha consoles).
Connect the battery as shown
in the SUMMARY
OF CONNECTIONS
diagram.