Output Relay Displays
4
Enter Relay No.
(00 = Quit)
01
Benge being programmed.
02
AEVZLZT
STT
00
000
02.
AEVZLZT
STP
-
-— 0 00
02 Relay Action
No Response
0
02 Start Event
Not Used
0
02 Start:
Zn List
No List
0
02 Start:
ZnTyp
Zone Disabled 00
02 Stop:
Zn List
No List
0
02 Stop:
Zn Typ
Zone Disabled 00
02
AEVZLZT
STT
00
000
02
AEVZLZT
STP
- —
000
Upon entering field *80, this screen will appear. Enter the Relay Number 01 or 02
for a 4229, or 01, 02, 03, or 04 for a 4204 (or 00 to end these entries). Press the
This screen displays a summary of the current relay START programming (for this
example, relay 02 has been selected). Press the [*] key to advance.
This screen displays a summary of the current relay STOP programming. Press
the [*] key to advance.
Action (A): Enter the desired relay action. Press the [*] key to advance.
0 = Not Used
2 = Close and Stay Closed
1 = Close for 2 seconds
3 = Continual
Pulses
(1 sec) On and Off
Event (EV): Enter the event to START the relay. Press the [*] key to advance.
0 = Not used
2 = Fault
1 = Alarm
3 = Trouble
Zone List (ZL): If a zone list will be used to START the relay action, enter the
zone list number (to be programmed in field *81): 1, 2, or 3. If not used, enter 0.
Press the [>] key to advance.
Zone Type/System
Operation (ZT): If a zone type or system operation will
be used to START the relay action, enter the appropriate two digit code. If not,
enter 00. Press the [*] key to advance.
CHOICES
FOR
ZONE
TYPES
00 = Not Used
01 = Entry/Exit
05 = Trouble Day/Alarm Night
08 = 24 Hr Aux
03 = Perimeter
06 = 24 Hr Silent
09 = Fire
04 = Interior Follower
07 = 24 Hr Audible
10 = Interior w/Delay
CHOICES
FOR
SYSTEM
OPERATION
20 = Arming—Stay
33 = Any Burglary Alarm
38 = Chime
21 = Arming-Away
34 =Code+#+7Key Entry
39= Any Fire Alam
22 = Disarming (Code + OFF)
35=Code+#+8Key Entry
40 = Bypassing
31 = End of Exit Time
36 = At Bell Timeout**
41 = AC Power Failure
32 = Start of Entry Time
37 = 2 times Bell Timeout**
42 = System Battery Low
**Or at Disarming, whichever occurs earlier.
"Restore of" Zone List (ZL): If a zone list will be used to STOP the relay ac-
tion, enter the zone list number (to be programmed in field *81): 1, 2, or 3. If not
used, enter 0. Press the [>] key to advance.
Zone Type/System
Operation (ZT): If a zone type or system operation will
be used to STOP the relay action, enter the appropriate two digit code (see the
"ZT" choices listed above). If not, enter 00. Press the [*] key to advance.
This screen again displays a summary of the current relay START programming .
Press the [>] key to advance.
This screen again displays a summary of the current relay STOP programming.
Press the [*] key to return again to the first screen so that the next relay number
to be programmed can be entered, or enter [0][0] to end relay programming.
=95—