ype 0
24-hour Silent Alarm
24-hour
Audible
Alarm
ype 08
N a z ° &
be
|
Auxiliary
Alarm
ype O
Supervised
Fire
i
Interior w/Delay
| 4
Arm-Stay
i
Arm-Away
i
Disarm
No Alarm
Response
This zone type sends a report to the Central Station but provides no console
display or sounding.
T h i
i
i
ini
This zone type sends a report to the Central Station, and provides a rapid
beeping sound at the console, and an audible external alarm. This zone type is
ll
ign
zone
that h
n Emergen
n.
This zone type sends a report to Central Station and provides a rapid beeping
sound at the console. (No bell output is provided). This zone type is usu-
lly assigned to a Zone containing a
n for
in personal emergenci
r
a zone containing
monitorin
vices such as water
or
temperatur
nsor.
This zone type provides a fire alarm on short circuit and a trouble condition on
open circuit. The bell output will pulse when this zone type is faulted. This zone
type is always active and cannot be bypassed. This zone type can be assigned to
ntrol panel wired zon
ny zone in a wir
ne
ex
ion _modul
This zone type gives entry delay (using the programmed entry time), if tripped
when the panel is armed in the Away mode, regardless of whether or not an en-
try/exit delay zone was tripped first. This zone type is also active during Maximum
mode, but no entry delay is provided (an alarm occurs immediately if the zone is
tripped).
Exit delay is present for any arming mode.
This zone
type is
bypassed
automatically
when
the panel is armed
Stay or Instant .
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in arming the system in the STAY
mode when the zone is activated.
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in arming the system in the
AWAY mode when the zone is activated.
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in disarming the system when the
zone is activated.
This zone type can be used on a zone when an output relay action is desired, but
with no accompanying alarm (ex. lobby door access).
By using a 4281/5881 RF Receiver and the appropriate 5700/5800 series transmitters,
all of the above zone types are available for the wireless portion of the system.
20 Report Code
ist0O0 2nd00
00
20 Input Device
RF Trans. RF:
When the display shows the zone type you want, press [*] to advance
to...
Report Code (RC): The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For example, for a report
code of "3C", enter [0][3] for "3" and [1][2] for °C". Enter the numbers
and press [*] to advance to...
Input Device (In): For the hard wired zones of the Ademco
via30+
(HW), the auxiliary wired expansion zones on a 4219 or 4229 (AW), and
the zones for a 5700 system's transmitters (RF), the Input Device types
are automatically assigned (Panic, Duress, and Tamper inputs are not
applicable).
For a 5800 system's transmitters, "RF" is initially displayed, but should be
changed to "UR" (Unsupervised RF, enter 4) for units that can be carried
off-premises (e.g., No. 5801), or to "BR" (Button type RF, enter 5) for
small transmitters that cannot be supervised (e.g., Nos. 5802, 5802CP,
5803). Check the instructions that come with the transmitter for the
proper input. When all is okay, press [*] to advance to...
—-21-