Example
of
Output
Relay
Programming
Let
us
light an
indicator
when
any
one
of 3 specific
zones
are
faulted
or when
any
24 hour
aux.
zone
is disturbed.
We
want
to
turn off the indicator manually
without
affecting the arming
status
of the system.
In field *80 we choose Output Relay 01 and program the Action (A) to be "2"
(Close and stay closed). The Event we are looking for to start the relay action is a
fault, so we will program "2" in (EV). We will use Zone List 1 for the 3 specific
zones, so will program "1" in (ZL), (and will program these 3 zones in field *81's
Zone List 1).
The second condition for turning on the indicator is triggering a 24 hour aux. zone
(Zone Type 08), so we will program (ZT) as "08".
To stop relay action and turn off the indicator, we do not want to use a restore of
any zone, so we will program a "0" for the "Restore of" Zone List (ZL). To choose a
manual entry of User Code + [#] + [7] to turn it off, we will program (ZT) as "34".
If no other relay is to be programmed we go to field *81 and program the 3 specific
zones in Zone List 1.
FOR
OTHER
EXAMPLES
SEE THE TABLE
ON
PAGE
44
*81
ZONE
LISTS
FOR
OUTPUT
RELAYS
Zone List Displays
Applicable only if field *25 is programmed for a 4229 or 4204...otherwise
skip this field.
Upon entering field *81, this screen will appear. Enter the Zone List Number 01,
:
02, or 03 to program (or 00 to end these entries). Press the [*] key to advance.
(00 = Quit)
01 | inthe following displays, zone list 03 has been selected for programming.
Zone List No.
Hy
4 Zone List selected.
(00 = Quit)
00 | 00 to advance.
To delete the zone list, enter 1 (Yes). All zones in the zone list will be deleted
ist?
0 Pelee
automatically and programming will return to the first screen.
O=No 1=Yes
0 | to save the zone list, enter 0 (No) to advance.
O=No 1=Yes
0 | To delete a zone or zones in a zone list enter 1 (Yes) to advance.
Notes:
°¢ Any list may include any or all of the system's zone numbers.
¢ A zone list can be assigned to more than one output relay.
if you only want to review what has been programmed previously,
enter [#][8][1]. The review can be advanced by using the [#] key.
When finished, enter [0][0] to quit. No programmed values can be
disturbed in this mode.
*82
CUSTOM
ALPHA EDITING (Also entered from field *56)
See ALPHA DESCRIPTION ENTRIES section on page 29.
*83
ADD/DELETE
5800 RF INPUT
IDs (Serial Nos & Sensor
Pts)
See procedure in last paragraph of field *56.
*92
MAXIMUM
NUMBER
OF
REPORTS
PER
ARMED
PERIOD
Enter:
0 fora maximum of 10 total alarm plus alarm restore reports,
or:
1 for an unlimited number.
DOWNLOAD
*94
DOWNLOAD
PHONE
NUMBER
INFORMATION
Enter up to 12 digits, 0-9, #+11 for '*', #+12 for '#', #+13 for a pause. Do
(*94, *95)
not fill unused spaces. If fewer than 12 digits entered, end field by
entering * (and press next field number). To clear field, press *94*.
*95
RING
DETECTION
COUNT
FOR
DOWNLOADING
Enter number of rings before control picks up phone line (or 0 or 15).
O=
disable station initiated download
1-14=
#of rings
15=
answering machine defeat
—~26—