Unit Data; Sensors; Temperatures And Sensors; Weekly Programme - Helios KWL 340 D Manual

Central ventilation unit

Advertisement

Available languages

Available languages

Installation and Operating Instructions
NOTE
Central ventilation unit – KWL 220/340 D

8.2.5 Unit data

The following unit data is displayed:
• Ventilation
• Heat exchanger status
• Relative humidity
• CO2/VOC
• Extension module (only if extension module is configured)

8.2.6 Sensors

The connected sensor data is displayed.

8.2.7 Temperatures and sensors

Graphical representation of the temperatures and connected sensors.
ⓘ In order to retrieve the data, it must first be updated using the
ⓘ The temperatures and sensors can be selected or deselected by clicking on the corresponding legend.
ⓘ If multiple sensors are connected, the sensor data from the sensor with the highest value will always be taken
over.

8.2.8 Weekly programme

• Activate/deactivate weekly programme
• Create/edit weekly programme
The ventilation profile changes in the following order by clicking on a field (cf. Fig. 47):
Ventilation profile "At home" (1x click)
Ventilation profile "Away from home" (2x clicks)
Ventilation profile "Intensive ventilation" (3x clicks)
Ventilation profile „Individual" (4x clicks)
Ventilation profile auf „Standby" setzen (5x clicks)
Delete ventilation profile (6x clicks); the previous ven-
tilation profile is automatically applied.
• Delete weekly programme
We would like to point out that you should only use the „Unit off" function in special cases! The ventilation system should
be switched on at all times to ensure fresh and healthy indoor air and to prevent moisture from condensing in the ven-
tilation ducts or structures.
8.3
Unit data

8.3.1 Ventilation unit status

The following ventilation unit status data is displayed or can be adjusted:
• Ventilation profiles
Status: Activate/deactivate ventilation unit.
• Last power failure
Displays the days since the last power failure.
• Operating time
Displays the operating time in days.

8.3.2 Time, Date

The following time and date data can be adjusted:
• Date
• Time
• Daylight saving time
• 24 hr format

8.3.3 Ventilation unit data

The following ventilation unit data is displayed:
• Model
• Series number
• Type
• Software version
• Rel. humidity sensors (number)
• CO2/VOC sensors (number)
• Alignment
• UUID
• Cloud service
• IP address
• Gateway
• Mask
8.4

Service menu

8.4.1 Temperatures

The current temperatures are displayed:
• Supply air
• Exhaust air
• Intake air
• Extract air
4x
24
button.
Fig. 47
3x
2x
1x
5x
EN