CHAPTER 3
PRODUCT
INFORMATION
Central ventilation unit – KWL 220/340 D
3.1

Unit overview

10
Å
7
î
8
Supply air fan
Exhaust air fan
ù
Unit door
ä
Design panel
ë
ö
Supply air fan body
Supply exhaust fan body
ü

3.1.1 Model Label

The type plate is located on the upper inside next to the terminal box (7).
3.2

Functional description

The unit has a heat exchanger. The heat exchanger continuously extracts heat from the stale room air (extract air) and
transfers this heat to the fresh intake air, which flows into all rooms connected to the duct system as pre-heated, filtered
Bei Verwendung eines Heizregisters, muss das Rohrsystem 0,5 m vor und nach dem Heizregister
supply air. The stale air is extracted from the connected rooms via the duct system. It flows through the duct system
mit temperaturbeständigem bzw. nicht brennbarem Rohr versehen werden (z.B. Wickelfalzrohr)
back to the ventilation unit, gives off heat and is led outside through the exhaust air duct (see Fig. 2).
The heat recovery efficiency depends on the factors of humidity and the temperature difference between intake and
extract air.
ù
Supply air
Zuluft
2
T6
Extract air
Abluft
Externe Fühler
External sensor
(Raumseitige Installation)
(Room-side installation)
CO2 sensor
CO2-Fühler
Feuchte/Temperaturfühler
Humidity/temperature sensor
VOC-Fühler
VOC sensor
Non-combustible duct (e.g. spiral duct)
ù
Insulated duct system IsoPipe
IP 125/2000 (accessories KWL 220 D)
IP 160/2000 (accessories KWL 340 D)
Short duct connector Ø125/160
ä
RVBD 125 K (accessories KWL 220 D)
RVBD 160 K (accessories KWL 340 D)
16
16
11
15
11
15
1
ö
5
ù
2
Æ
10
Terminal box cover
Å
Heat exchanger
î
Bypass
Ø
Filter Extract/Intake air Coarse 75 %
Æ
11
Supply air filter ePM1 50 %
Ball siphon
12
ö
5
(T7)
Rücklauf
WW-Register
1
(4x)
T4
T1
ù
2
Ø125/160
®
7
ä
3
ë
4
Ø
9
ü
6
14
14
Casing
13
14
Mounting bracketl
Cable gland
15
16
Knurled screws
Abb. KWL 220/340 D Rechts
T3
ù
ä
F-AB
2
3
T2
ù
2
Exhaust air
Fortluft
Electrical heating element
ö
EHR-R 1.2/125 (accessories KWL 220 D)
EHR-R 2.4/160 (accessories KWL 340 D)
T1 Extract air temperature sensor
T2 Exhaust air temperature sensor
T3 Intake air temperature sensor
T4 Supply air temperature sensor
T6 Air temperature duct sensor / KWL-LTK (access.)
Fig. 1
13
13
14
14
12
12
Fig. 2
ù
2
Intake air
Außenluft

Advertisement

loading

This manual is also suitable for:

Kwl 220 d