Kohler KD62V12A Operation And Maintenance Manual page 217

Table of Contents

Advertisement

SPN
516245
516245
516245
516245
516245
516511
677
677
677
677
516512
516369
516369
516369
516369
516251
516251
1076
516253
1076
1076
516328
1076
516328
1076
1076
1076
516256
516256
516255
516258
516255
516255
516336
516255
516336
516255
516255
KD62V12A 33521061401_1_1 EN_US
2023-10
FMI
6
Smart sensor supply relay - Critical high output current
5
Smart sensor supply relay - Open circuit
3
Smart sensor supply relay - Short circuit to battery
4
Smart sensor supply relay - Short circuit to ground
11
Smart sensor supply relay - Electrical error
31
Starters - Not connected in the output 1 to ECU
6
5
3
4
31
Starters - Not connected in the output 2 to ECU
6
5
3
4
0
Volume control valve - Current remains above the set point
1
Volume control valve - Current remains below the set point
6
Volume control valve - Critical high output current
0
Volume control valve - PWM signal - High limit reached
5
3
Volume control valve - Short circuit to battery (high side)
3
Volume control valve - Short circuit to battery (low side)
4
Volume control valve - Short circuit to ground (high side)
4
Volume control valve - Short circuit to ground (low side)
11
Volume control valve - Load is short circuited
0
Volume control valve - Critical overcurrent
1
Volume control valve - Critical undercurrent
0
Volume control valve 2 - Current remains above the set point
1
Volume control valve 2 - Current remains below the set point
6
Volume control valve 2 - Critical high output current
0
Volume control valve 2 - PWM signal - High limit reached
5
3
Volume control valve 2 - Short circuit to battery (high side)
3
Volume control valve 2 - Short circuit to battery (low side)
4
Volume control valve 2 - Short circuit to ground (high side)
4
Volume control valve 2 - Short circuit to ground (low side)
31
Volume control valve 2 - Load is short circuited
0
Volume control valve 2 - Critical overcurrent
© 2023 by Kohler Co. All rights reserved.
Text
Starter - Critical high output current
Starter - Open circuit
Starter - Short circuit to battery
Starter - Short circuit to ground
Starter 2 - Critical high output current
Starter 2 - Open circuit
Starter 2 - Short circuit to battery
Starter 2 - Short circuit to ground
Volume control valve - Open circuit
Volume control valve 2 - Open circuit
Appendix
Error code