Maintenance
6000 - Electrical and control system
Inspection
Fig. 95: Battery charging alternator
u Clean the battery charging alternator from body to fan with an air blow gun.
u Inspect overall condition of the battery charging alternator.
u Check for loose cable connections.
u Clean the alternator pulley with an air blow gun.
u Check pulley for external damage or excessive play with the rotor.
u Record and report any defect.
If defect is detected:
u Make sure that authorized service personnel replace the battery charging alternator.
5.11.3 Inspecting belt drive system of battery charging alternator —
SL1-6231
Previous tasks
Make sure that the following preconditions are met:
q Preparatory maintenance activities are fulfilled.
p. 100)
q Cover of battery charging alternator is removed.
battery charging alternator — SL1-6235, p. 175)
Specific safety instructions
WARNING
Entanglement of fingers in the belt during the assembly of auxiliaries!
Risk of injury by crush.
u Observe local regulations, site rules, and safety notes.
u Wear proper personal protective equipment.
u Use assembly and lifting devices.
172
© 2023 by Kohler Co. All rights reserved.
(→ 5.4 Preparatory maintenance activities,
(→ 5.11.5 Removing and installing cover of
KD62V12A 33521061401_1_1 EN_US
2023-10