EZ-SCREEN
Type 2 Light Screen
Emitter Cordset
EZ-SCREEN Type 2 emitters have an 8-pin cordset, but only three conductors are
required:
Brown = +24 V dc
Blue = 0 V dc
Green/Yellow = GND
Note: The reset switch must be a normally closed switch that is held open for approximately 1/4 second, then closed to
accomplish the reset. The switch must be capable of switching 10 to 30 V dc at 30 mA.
The other wires are for an optional hookup that allows for parallel connection (color-for-color) to the receiver cable. This optional
hookup provides for sensor interchangeability (or swapability) that facilitates installing either sensor at either QD connection. Besides
providing similar cabling, this wiring scheme is advantageous during installation, wiring, and troubleshooting.

4.2.1 Sensor Interchangeability

The figures and table below illustrate a wiring option that provides sensor interchangeability (or swapability)—the ability to install
either sensor at either QD connection.
The resulting installation provides the ability to swap the emitter and receiver position. This wiring option provides advantages during
installation, wiring, and troubleshooting.
To use this option, connect all emitter wires in parallel (color-for-color) to the receiver cable via individual wires or the CSB.. splitter
cordset (can be used with only emitters and receivers with similar connectors, such as a pair with 8-pin quick disconnects or a pair with
5-pin quick disconnects.).
Model CSB.. splitter cordsets and DEE2R.. double-ended cordsets allow easy interconnection between an EZ-SCREEN Type 2 receiver
and emitter, providing a single homerun cordset.
24
Receiver Cordset
Do not connect any wires to the machine control circuits (that is, OSSD outputs)
at this time.
For the initial checkout, only the following EZ-SCREEN Type 2 receiver conductors
should be connected:
Additionally, connect the external reset switch, if used, or test signal contact to
the Reset/Test wire (violet) and to 24 V dc.
www.bannerengineering.com - Tel: 763.544.3164
Brown = +24 V dc
Blue = 0 V dc
Green/Yellow = GND