9 Troubleshooting

9.1 Lockout Conditions

A Lockout condition causes all of the EZ-SCREEN LS Basic OSSD outputs to turn or remain Off, sending a stop signal to
the guarded machine. Each sensor provides diagnostic error codes to assist in the identification of the cause(s) of lockouts
(see
Receiver Error Codes and Emitter Error Codes ) ).
The following tables indicate a sensor lockout condition:
Table 9: Receiver Lockout Conditions
Run mode indicator
Status indicator
Alignment indicators
Diagnostic display
If both the emitter and its corresponding receiver do not have the same scan code setting, the receiver indicates that Beam
1 is blocked (the Diagnostic display indicating "C" "H" "1" as shown in
lockout and can occur if the Scan Code input is not wired the same for both sensors or if the EDM circuit has not been re-
wired for one-channel monitoring in retrofit installations of two-channel EDM applications (see the warning in
Device Monitoring Hookup

9.2 Recovery Procedures

To recover from a Lockout condition, correct all errors, power the sensor down, wait a few seconds, and then power the
sensor back up.
WARNING: Lockouts and Power Failures
Power failures and Lockout conditions are indication of a problem and must be investigated immediately
by a Qualified Person
other safeguards is dangerous and could result in serious injury or death.
WARNING: Shut Down Machinery Before Servicing
The machinery to which the Banner device is connected must not be operating at any time during major
service or maintenance. This may require lockout/tagout procedures (refer to OSHA1910.147, ANSI
Z244-1, ISO 14118 or the appropriate standard for controlling hazardous energy). Servicing the Banner
device while the hazardous machinery is operational could result in serious injury or death.

9.2.1 Receiver Error Codes

Diagnostic
Error Description
Display
10
Output Error
Error is caused by:
one or both outputs
being shorted to a
power supply (high or
low)
by shorting OSSD 1 to
OSSD 2
by an overload (greater
than 0.5 A)
9
A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and
experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.
10
Multiple-digit codes are sequential, followed by a pause.
54
Off
Flashing Red
Off
Error code (flashing)
on page 42).
9
. Attempts to continue to operate machinery by bypassing the Banner device or
Cause of Error and Appropriate Action
www.bannerengineering.com - Tel: 763.544.3164
Table 10: Emitter Lockout Conditions
Status indicator
Diagnostic Display
Receiver
on page 49). This is not considered a
Disconnect the OSSD loads and cycle power to the receiver.
If the error clears, the problem is in the OSSD load(s) or in the
load wiring.
If the error continues with no load connected, replace the
receiver.