Graph Monitor (Connect No.0 To Connect No.7 When Multiplex Module Is Used) - Mitsubishi Electric GOT-A900 Series Operating Manual

Table of Contents

Advertisement

12. OPERATION OF EACH SPECIAL MODULE MONITOR SCREEN
12.18.7 Graph monitor (connect No. 0 to connect No. 7 when multiplex module is used)
1)
2)
No.
1)
The connect number of the monitor being used is displayed.
The current output value, a value between 0 to 4000 for the digital output
2)
value of each channel, is displayed in a graph as a percentage ranging from
0 to 100%.
When the A60MXT is used, the temperature detection value of each channel
3)
is displayed.
A "!" is displayed when a watchdog timer error occurs.
A "!" is displayed when an error occurs.
When the A60MXT is used, "1" is displayed when a temperature was input
that exceeds the temperature range set according to the digital output value
4)
set for each channel.
When the A60MXT is used, "1" is displayed when a temperature was input
that exceeds the measurement temperature range set for the measurement
range of each channel.
The set status of the data format for each channel is displayed.
5)
The specified conversion enabled/disabled status for each channel is
displayed.
5)
Contents of display
12 - 56
GOT
MELSEC
Buffer memory address to
reference (hexadecimal)
180 to 1FF
200 to 27F
0
10 to 17