9. OPERATION OF THE VARIOUS SYSTEM MONITOR SCREENS

9.2.3 Deleting a registered device

[Operation procedure]
Display Device Monitor screen.
Display device setting menu screen.
DEVICE MONITOR
NETWK No.[ 0]
DEVICE
TEST
(Batch deletion)
(Random deletion)
ALL CLR
Display device deletion screen.
X
Y
F
D
Z
V
G
: Select input area
Character: Input device name and no.
Move (return) to
Device Monitor screen.
The operation of deleting (erasing) the entry of the device being monitored with the
Entry Monitor screen is explained below.
The following two methods can be used to delete the registered device.
• Random deletion .......... Deletes only one specified device.
• Batch deletion ............... Deletes all devices that are currently registered.
SET (Touch)
TEST
MENU FORM
SET
STATION[FF]
DELETE
ALL CLR
CANCEL
DELETE
(Touch either key.)
DEVICE [
] [
]
M
S
B
W
R
A
T
C
E
AC
DEL
(Touch: Input confirmation)
* If there is a
touching the
..............
See Sec. 9.2.2.
(1) Specify the device to be deleted.
* Match the data to be enterd; the touch key
display at the bottom of the screen will change.
*1 Data being entered can be cleared by the following
keys.
(*1)
AC : Clears all data being entered to the object
DEL : Clears one character at the cursor position.
9 - 9
at the upper left of the screen,
returns to the monitor screen.
area.