Operation Monitor - Mitsubishi Electric GOT-A900 Series Operating Manual

Table of Contents

Advertisement

12. OPERATION OF EACH SPECIAL MODULE MONITOR SCREEN

12.23.2 Operation monitor

1)
2)
3)
No.
1)
The feed current value is displayed.
2)
The axis speed is displayed.
3)
The axis operation status is displayed.
4)
The axis error No. is displayed when an axis error occurs.
5)
The axis warning No. is displayed when an axis warning occurs.
The M code (valid M code) that is set in the data during
6)
positioning is displayed.
Positioning data No. during positioning is displayed.
7)
(The actual data No. is also displayed when specified indirectly.)
The positioning identifier of the positioning data during
positioning is displayed.
Bit
15
8)
9)
10)
11)
7)
Contents of display
to
8
7
6
5
4
3
to
0
9)
11)
10)
8)
Operation pattern
Acceleration time no.
Deceleration time no.
Data control method
4)
8)
9)
12 - 81
MELSEC
5)
6)
10)
11)
Buffer memory address
to reference (decimal)
Axis 1
Axis 2
800
900
801
901
812
912
813
913
809
909
807
907
808
908
806
906
835
935
838
938
GOT
Axis 3
1000
1001
1012
1013
1009
1007
1008
1006
1035
1038

Advertisement