1. OVERVIEW
Functions
Brightness/
Adjusting the brightness/contrast
contrast
of a monitor screen
adjustment
Message
display
Selecting a message display.
selection
Copying the screen and OS data
Screen &
between the internal memory and
OS copy
memory card.
Setting a use environment of the
Setup
Utility
GOT
function
Running diagnostic checks on
Self-test
GOT hardware
Memory
Displaying GOT memory
information
information.
Clock
Setting the clock.
Screen
Displaying the display area
cleanup
cleanup screen.
Defining a password for limited
Password
access to the utility menu screen.
Ladder
Sequence program monitoring
monitor
using ladder signals
Decimal and hexadecimal display
Display
of word device values
Ladder
switching
monitor
Device comment display
function
Device
Changing of device values
changing
Print out
Printing of ladder
Entry
Monitoring of current values by
monitor
pre-registering monitor devices
Monitoring of n points of current
Batch
values subsequent to specified
monitor
device
Monitoring of m points of current
values, set values, contact points,
T/C monitor
and coils subsequent to specified
device
Monitoring of x points of current
values subsequent to specified
BM monitor
buffer memory of specified special
module
System
Setting/resetting of bit device
monitor
Changing of current value for
function
Data
buffer memory of word device
editing
Changing of current value for T/C
using test
(can be used while monitoring
operation
T/C)
Changing of set value for T/C (can
be used while monitoring T/C)
Changing of device values using
Quick test
quick test
Device comment display
Display
Decimal and hexadecimal display
switching
of word device values and buffer
memory values
Special module
Monitoring of buffer memory of
monitor function
special module on special screen
Network monitor
Monitoring of network status of
function
MELSECNET/B, (II) or /10
Sequence program in the ACPU is
List editor function
list edited.
*1 When connected to the PLC CPU without clock function (FX
cannot be set. Also, the clock function can be used with the FX
is used.
*2 When connected to the PLC CPU without clock function, additional function cannot be set.
*3 You can set the clock function only when you are using A9GT-RS2T, which includes a clock element.
*4 T/C set values and coils cannot be monitored.
(c) Connection with FXCPU, third party PLC or microcomputer
Ref.
Section
CPU direct connection
Section
4.3
Section
4.3
Section
4.4
Section
4.5
Section
4.6
Section
4.7
Section
4.8
Section
4.9
Section
4.10
Section
6.2.1
Section
6.2.3
Section
6.2.4
Section
6.2.5
Section
9.2
Section
9.3
Section
9.4
Section
9.5
Section
9.6
Section
9.6.2
Section
9.1.2
Ch. 11
Ch. 15
Ch. 19
FXCPU
Other PLC connection
∗ 1
∗ 4
, FX
, FX
0
0N
and FX
2
1 - 4
MELSEC
Microcomputer connection
∗ 2
, FX
, FX
), additional function
1
2NC
0S
, when cassette for the realtime clock
2N
GOT
∗ 3

Advertisement

Table of Contents
loading

Table of Contents