A 9 pin D connector located on the rear panel labelled REMOTE CTL
provides 6 parallel control inputs for remote control of some of the model
5010-SIE functions. The pinout of the D connector is as follows:
VCG ENABLE Provides an alternate method of turning the character
inserter generator On and Off. The character inserter is toggled
On or Off by a high to low transition on this input. This input has
equal priority with the front panel CHAR GEN ON/OFF key.
ON AIR TALLY INPUT When closed to ground all the VCG windows will
be turned off.
Model 5010-SIE Source ID Encoder Manual
Pin
Description
1
Frame Ground
6
not used
2
VCG On/Off
7
not used
3
On Air Tally Input
8
not used
4
not used
9
reserved - do not connect
5
reserved - do not connect