The following document describes the hardware changes to the 5010-SIE related to adding a bypass
relay on the VITC generator output. References to the 5010-SIE manual are to version 1.0 printed Feb.
1996.
Section 2.1.1 should be changed to read:
2.1.1 Vertical Interval Timecode Video Connections
The VITC Generator program input is fitted with a hardware bypass relay which will pass the program
video through to VITC output B when there is a power loss in the 5010-SIE.
PGM INPUT: A BNC for input for program video onto which vertical interval time code is to be
inserted. When the relay is in the bypass condition, video applied to this input will be
passed through to the VITC OUT B connector. When the bypass relay is in the active
condition, this input is internally terminated with 75 ohms, and the program video will
pass through the VITC Generator circuitry.
VITC OUT A A BNC connector which contains the PGM INPUT video with vertical interval time code
inserted. This input is active only when the bypass relay is in the active condition.
(Power applied to the 5010-SIE)
VITC OUT B: A BNC connector which contain the PGM INPUT video with vertical interval timecode
inserted when the bypass relay is in the active condition. (Power applied to the
5010-SIE). When the relay is in the bypass condition, (no power to the 5010-SIE) the
VITC OUT B connector will contain the PGM INPUT video with nothing inserted.
Date of Issue: September 26, 2001
Model 5010-SIE Source ID Encoder Manual
5010-SIE Manual Change Sheet 1.0-1
Page 1 of 1