Care And Handling Of Optical Fiber; Safety - evertz 2405EO Instruction Manual

Smpte259m re-clocking electrical to fiber converter
Hide thumbs Also See for 2405EO:
Table of Contents

Advertisement

There is one SC/PC (shown), ST/PC or FC/PC female connector with reclocked serial
component video outputs, compatible with the SMPTE 259M, DVB-ASI or SMPTE 310M
standard. This connector is the optical output from the 2405EO as shown in section 3.3.
The 2405EO comes with an auto-ranging DC voltage adapter that automatically senses the
input voltage. Power should be applied by connecting a 3-wire grounding type power supply
cord to the power entry module on the DC voltage adapter.
minimum 18 AWG wire size; type SST marked VW-1, maximum 2.5 m in length. The DC cable
of the voltage adapter should be connected to the DC power jack on the rear panel. A green
LED located beside the power connector will be illuminated when there is power applied to the
2405EO.
2.1.

CARE AND HANDLING OF OPTICAL FIBER

2.1.1. Safety

!
Background colour: yellow
Triangular band: black
Symbol: black
The laser modules used in the Evertz fiber optic modules are Class I, with a maximum output power of
2mW, and wavelengths of either 1310 nm or 1470 nm to 1610 nm.
2.1.2. Assembly
Assembly or repair of the laser sub-module is done only at Evertz facility and performed only by Evertz
technical personnel.
2.1.3. Labeling
Certification and Identification labels are combined into one label and it is located in the middle of the
chassis, on the bottom, close to rear. Date of manufacture can be traced by bar code provided on the
label.
2405EO SMPTE259M Re-Clocking Electrical to Fiber Converter
CLASS 1 LASER PRODUCT
Revision 2.0
2400 Series Fiber Converter Manual
The power cord should be
2405EO-3