8.2.

CONFIGURING THE MODULE FOR FIRMWARE UPGRADES

UPGRADE:
The UPGRADE switch is located at jumper J16 on the front side of the main module
and is used when firmware upgrades are being done to the module. For normal
operation it should be switched to the RUN position as shown in the diagrams
above. See the Upgrading Firmware chapter in the front of the binder for more
information.
To upgrade the firmware in the module unit pull it out of the frame. Move Jumper
J16 into the UPGRADE position. Install the Upgrade cable provided (located in the
vinyl pouch in the front of this manual) onto header J24 at the card edge. Re-install
the module into the frame.
Firmware chapter. Once the upgrade is complete, remove the module from the
frame, move J16 into the RUN position, remove the upgrade cable and re-install the
module. The module is now ready for normal operation.
The Upgrade baud rate for the 7772MFX-HD module is 115200 baud.
8.3.

SELECTING WHETHER THE GENLOCK REFERENCE INPUT IS TERMINATED

TERM:
The TERM jumper J5 (located at the rear of the sub-board) is used to terminate the
genlock loop input. When it is in the 75R position a 75 ohm terminating resistor will
connect the input to ground. When it is in the HI-Z position the genlock input will be
high impedance.
8.4.

SELECTING WHETHER THE INPUT VIDEO IS BYPASS

BYPASS:
The BYPASS jumper J25, located at the front of the module, enables the bypass relay
to always remain in the closed position.
7772MFX-HD JPEG2000 SD & HD Encoder and Decoder
Run the upgrade as described in the Upgrading
Revision 1.2
7700 MultiFrame Manual
7772MFX-HD - 33