8.1.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
FRAME STATUS:
The FRAME STATUS jumper (J22) located at the front of the main module
determines whether local faults (as shown by the Local Fault indicator) will be
connected to the 7700FR frame's global status bus.
To monitor faults on this module with the frame status indicators (on the PS FRAME
STATUS LEDs and on the Frame's Fault Tally output), install this jumper in the On
position (default).
When this jumper is installed in the Off position, local faults on this module will not
be monitored.
7772MFX-HD - 32
EVERTZ (B) 7700PH4
SFF POWER
GND
+12V
Figure 8-1: Location of Jumpers – Rev B Main Board