7.1.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
FRAME STATUS
The FRAME STATUS jumper J5 located at the front of the main module determines
whether local faults (as shown by the Local Fault indicator) will be connected to the
7700FR frame's global status bus.
To monitor faults on this module with the frame status indicators (on the PS FRAME
STATUS LED's and on the Frame's Fault Tally output) install this jumper in the On
position. (Default)
When this jumper is installed in the Off position, local faults on this module will not
be monitored.
7.2.
CONFIGURING THE MODULE FOR FIRMWARE UPGRADES
Firmware updates can be performed using the Upgrade menu item on the Utilities menu (see section
6.6.4) or using the UPGRADE jumper.
UPGRADE
The UPGRADE switch is located on the back side of the main module (On the rear
of the J7 jumper location near the front card edge) and is used when firmware
upgrades are being done to the module. For normal operation it should be switched
to the RUN position as shown in the diagrams above. See the Upgrading Firmware
chapter in the front of the binder for more information.
The silkscreen on the front side of the board for J7 is incorrect.
orientation of the switch is shown in Error! Reference source not found. and Figure 5
To upgrade the firmware in the module unit pull it out of the frame. Move Jumper J7
into the UPGRADE position. (Install the Upgrade cable provided (located in the
vinyl pouch in the front of this manual) onto header J2 at the card edge. Re-install
the module into the frame. Run the upgrade as described in Upgrading Firmware
chapter. Once the upgrade is completed, remove the module from the frame, move
J7 into the RUN position, remove the upgrade cable and re-install the module. The
module is now ready for normal operation.
7.3.
SELECTING WHETHER THE GENLOCK REFERENCE INPUT IS TERMINATED
TERM
The TERM jumper J21 located at the rear of the module is used to terminate the
genlock loop input. Then it is in the 75R position a 75 ohm terminating resistor will
connect the input to ground. When it is in the HI-Z position the genlock input will be
high impedance.
7710UC-KF HD Key/Fill Up Converter
Revision 0.2
7700 MultiFrame Manual
The correct
7710UC-KF-21