7.4.1. Sets the Program Number
Transport Stream Control
TSID
-1
0
9999
7.4.2. Reset the TS Statistics
Transport Stream Control
TSST
0
1
7.5.
CONFIGURING THE HEADPHONE MONITOR
The Headphone Monitor menus are used to configure parameters associated with the headphone jack on
the module. The chart below shows the items available in the Headphone Monitor menu. Sections 6.4.1
to 6.4.2 provide detailed information about each of the menu items.
HVOL
Headphone volume
HSRC
Headphone source
7.5.1. Setting the Headphone Volume
Headphone Monitor
HVOL
HV00 to HV15
HV07
7772MFX-HD JPEG2000 SD & HD Encoder and Decoder
If there are multiple programs in the ASI stream, this function allows
the user to select which program number to be used.
-1 indicates that the card will automatically tune to the first program in
the MPEG-2 TS that carries JPEG2000.
The default value is –1.
The 7772MFX-HD collects TS statistics referring to lost packets,
errors, etc.
This control will reset the statistics to 0.
Select 0 to keep the statistics as is.
Select 1 to reset the statistics.
Sets the volume for the headphone.
Selects the source for the headphone monitoring
This control enables the user to set the headphone volume to one of
16 levels.
Total adjustment range is over 50 dB. Level 00 is the lowest volume
and is effectively mute.
Revision 1.2
7700 MultiFrame Manual
7772MFX-HD - 27