Selecting Whether Module Will Be Controlled From The Local Controls Or Through The; Ista Link Interface; Configuring The Module For Firmware Upgrades - evertz 7700 Manual

Sd/hd re-clocking fiber to electrical converter
Hide thumbs Also See for 7700:
Table of Contents

Advertisement

5.4.
SELECTING WHETHER MODULE WILL BE CONTROLLED FROM THE
LOCAL CONTROLS OR THROUGH THE VISTALINK
The MASTER jumper selects whether the module will be controlled from the local user controls or through
the VistaLINK
interface.
®
MASTER: When this jumper is installed in the LOCAL position, the card functions are controlled through
the local jumpers.
When this jumper is installed in the REMOTE position, the card functions are controlled through
the VistaLINK
enabled. This LED is intended to alert the user that local controls are not currently active.
5.5.

CONFIGURING THE MODULE FOR FIRMWARE UPGRADES

UPGRADE:
The UPGRADE jumper is used when firmware upgrades are being done to the module. For
normal operation it should be installed in the RUN position (see NOTE 1 below). See the
Upgrading Firmware section of this manual for more information.
To upgrade the firmware in the module unit pull it out of the frame. Move the UPGRADE
jumper into the UPGRADE position (see NOTE 1). Install the Upgrade cable provided (located
in the vinyl pouch in the front of this manual) onto the SERIAL header at the card edge. Re-
install the module into the frame. Run the upgrade as described in the Upgrading Firmware
section of this manual. Once the upgrade is complete, remove the module from the frame,
move the UPGRADE jumper into the RUN position, remove the upgrade cable and re-install
the module. The module is now ready for normal operation.
NOTE 1: The Rev (A) boards have incorrect labeling for the RUN / UPGRADE modes. The jumper
labels shown in Figure 4-1 are correct. On Rev (A) boards, for normal RUN operation set the
jumper to the UPGRADE position (as shown on the board label - away from the front of the
module). For UPGRADE operation the jumper must be set to the RUN position (as shown on
the board label - closest to the front of the board).
7707OE-HD SD/HD Re-Clocking Fiber to Electrical Converter
interface. The adjacent yellow LED will be On when VistaLINK
®
Revision 1.2.2
7700 MultiFrame Manual
INTERFACE
®
control in
®
7707OE-HD-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

7707oe-hd

Table of Contents