Controlling The Circle Size (Circle Centred, Aspect Ratio Off); Controlling The Circle Size And Position (Circle Centred, Aspect Ratio On); Controlling The Circle Size And Position (Circle Not Centred, Aspect Ratio Off)3-23; Controlling The Circle Size And Position (Circle Not Centred, Aspect Ratio - evertz 9590 Instruction Manual

Graticule generator, high definition graticule generator
Table of Contents

Advertisement

3.8.3.2. Controlling the Circle Size (Circle Centred, Aspect Ratio Off)

Setup menu
Force centre
Mode menu
Aspect ratio
Mode menu
Centre
Size
When the circle is centred and aspect ratio MODE is Off, the left shaft encoder is used to
adjust the height and the right shaft encoder is used to adjust the width about the centre of the
raster.

3.8.3.3. Controlling the Circle Size and Position (Circle centred, Aspect Ratio On)

Setup menu
Force centre
Mode menu
Aspect ratio
Or
Setup menu
Force centre
Mode menu
Aspect ratio
Mode menu
Centre
Size
When the circle is centred and aspect ratio MODE is On, the left and right shaft encoders are
used to adjust the overall size of the circle proportionately about the centre of the circle while
maintaining the aspect ratio selected.

3.8.3.4. Controlling the Circle Size and Position (Circle not centred, Aspect Ratio Off)

Setup menu
Force centre
Mode menu
Aspect ratio
Mode menu
Centre
When the circle centring is Off and aspect ratio MODE is Off the position and the H and V size of the circle
lines can be positioned independently.
Size
The left shaft encoder is used to adjust the height of the circle, and the right shaft encoder is
used to adjust the width of the circle.
Position The left shaft encoder is used to adjust the vertical position of the circle, i.e. move the circle up
or down, and the right shaft encoder is used to adjust the horizontal position of the circle, i.e.
move the circle left or right.

3.8.3.5. Controlling the Circle Size and Position (Circle not centred, Aspect Ratio On)

Setup menu
Force centre
Mode menu
Aspect ratio
Mode menu
Centre
When the circle centring is Off and aspect ratio mode is On the position and overall size of the circle can
be adjusted proportionately about the centre of the circle based upon the aspect ratio selected.
RACK MOUNT PANEL OPERATION
Models 9590 & HD9590 Graticule Generator Manual
no
Setup menu
off
Mode menu
or
H + V
Yes
1:1
4:3
14:9
16:9
No
1:1
4:3
14:9
16:9
H + V
no
off
off
No
1:1
4:3
14:9
16:9
off
Force centre
yes
Aspect ratio
off
1.67:1
1.85:1
2.35:1
1.67:1
1.85:1
2.35:1
1.67:1
1.85:1
2.35:1
Page 3-23