Select digital 4:3 when you are working with normal aspect ratio video and you want to define the 4:3
aspect ratio according to the clean aperture.
Select digital 16:9 when the input video has been compressed from a 16:9 format to a 4:3 format and you
want to define the 16:9 aspect ratio according to the clean aperture. Objects will be drawn in their
compressed state, so that they will appear normal when the video is expanded again.

4.2.5. Choosing the Object Blink Time

Obj blink =
short
This menu item sets how long objects blink when they are selected.
Select long when you want a selected object to blink for twenty seconds before it reverts back to being
displayed continuously.
Select short when you want a selected object to blink for three seconds before it reverts back to being
displayed continuously.
Select none when you want to disable object blinking.

4.2.6. Choosing How Line Numbers are Displayed

Ln disp =
int rel
When the selected video standard uses an interlaced raster, this menu item changes the format that the
front panel display uses to show line numbers.
Select int rel to view line numbers in an interlaced relative format. In this format lines are numbered
relative to the beginning of each field and shown with their field number. (E.g. in 525 line video, line 21F1
is the first line of active video in field 1, line 21F2 is the first line of active video in field 2)
Select int abs to view line numbers in an interlaced absolute format. In this format lines are numbered in
an interlaced raster with the line numbers relative to the beginning of the complete frame. (E.g. in 525 line
video, line 21 is the first line of active video in field 1, line 283 is the first line of active video in field 2)
When the video standard uses a progressive (non-interlaced) raster, this menu item is not available. Line
numbering is always done in a progressive system referenced to the beginning of the frame.

4.2.7. Choosing Where the Vertical Mask Starts in the VBI

Mask Start =
9F2
This menu item determines starting line in the vertical blanking interval for the mask object. Turn one of
the shaft encoder knobs to adjust the line number. Vertical interval line numbers before this line will NOT