3.1.5. Status Indicators

There are 11 status indicators located on the front panel that show operational status of the Graticule
Generator at a glance.
Most of the LED's are common to the Standard and High definition Graticule Generators. The LEDs
above each of the object buttons indicate that the respective object is currently selected.
OBJ ON
Indicates that selected object is turned on.
PANEL LOCKED
Indicates that Graticule Generator front panel controls are locked against accidental
changes.
KEYER ACTIVE
Indicates that the Graticule Generator keyer is enabled. The enabled graticule
objects will be keyed into the video path.
PRESET ACTIVE
Indicates that one of the factory presets or user presets is currently in use. If any
object parameter is modified this LED will extinguish.
The video Standard LED's indicate what video standard the Graticule Generator is currently configured for.
The Standard Definition Graticule Generator has the following LEDs:
525
Indicates that the unit is currently configured for operation with 525 line/ 59.94 field per second
video.
625
Indicates that the unit is currently configured for operation with 625 line/ 50 field per second
video.
The High Definition Graticule Generator has the following LEDs:
1080
Indicates that the unit is currently configured for operation with 1080 active line video.
720
Indicates that the unit is currently configured for operation with 720 active line video.

3.2. FRONT PANEL SETUP MENU

The key to the operational flexibility of the Graticule Generator lies in the front panel SETUP menu system.
The SETUP menu system uses the 16 digit alphanumeric display and provides a quick, intuitive method of
configuring the Graticule Generator, guiding you to the correct setup for your application. The SETUP
Menu contains items that pertain to the overall operation of the Graticule Generator. In addition each
object is controlled by its own MODE and CTRL SEL settings. These context sensitive menus show only
the items applicable to the selected object for the current SETUP settings. See sections 3.2.12 to 3.8 for
information on controlling each of the objects through their MODE and CTRL SEL menus.
The two keys in the Setup key group (SETUP, ESC) are used to cycle through the various items on the
SETUP menu. The SETUP menu consists of a main menu with two or more choices for each menu item.
Figure 3-3 is an overview of the SETUP menu for the Standard Definition Graticule Generator. Figure 3-4
is an overview of the SETUP menu for the High Definition Graticule Generator. The menu items are
shown on the left with grey shading and the various choices are shown on the right with no background
shading.
Page 3-4
RACK MOUNT PANEL OPERATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd 9590

Table of Contents