Centring The Grid On The Raster; Controlling The Grid Attributes; Controlling The Grid White Level; Controlling The Grid Size (Grid Centred) - evertz 9590 Instruction Manual

Graticule generator, high definition graticule generator
Table of Contents

Advertisement

3.4.2.1. Centring the Grid on the Raster

Centre:
H + V
This item is used to control whether the grid object is centred on the raster or not. The centre item is only
available when the SETUP menu item force centre is set to off.
Select H + V to force the grid object to be centred on the raster.
Select off to allow the grid object to be moved off centre. In this MODE it is possible to independently
position each line on the grid, or to position and size the whole grid, depending what CTRL SEL item is
chosen.

3.4.3. Controlling the Grid Attributes

When the grid object is selected the CTRL SEL button is used to select which of its attributes (such as
white level, position, size, or individual lines of the object) will be adjusted by turning the shaft encoder
knobs. Press the CTRL SEL button until the desired CTRL SEL item is shown on the front panel. When
you have chosen the desired CTRL SEL item press the GRID button again or turn one of the shaft
encoder knobs to begin controlling the selected attribute of the grid.
The items that are shown in the grid CTRL SEL menu depend on the MODE settings and the settings in
the SETUP menu. In the sections describing the CTRL SEL items, the relevant settings from the grid
MODE and SETUP menus are shown where necessary.

3.4.3.1. Controlling the Grid White Level

Level
The white level can be adjusted in the range of "0" through "14", in single digit increments,
using either shaft encoder with "0" corresponding to "black" and "14" corresponding to "white".

3.4.3.2. Controlling the Grid Size (Grid Centred)

Setup menu
Force centre
Mode menu
Centre
Size
When the grid is centred, the left shaft encoder is used to adjust the height and the right shaft
encoder is used to adjust the width of the grid about the centre of the raster.

3.4.3.3. Controlling the Grid Size and Position (Grid not centred)

Setup menu
Force centre
Mode menu
Centre
When the grid centring is Off the H and V lines can be positioned independently in one of four modes.
V track
The left shaft encoder is used to adjust the vertical position of the grid, i.e. move the grid up or
down and the right shaft encoder is used to adjust the height of the grid.
RACK MOUNT PANEL OPERATION
Models 9590 & HD9590 Graticule Generator Manual
Off
no
H + V
no
off
Page 3-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd 9590

Table of Contents