Loading Factory Presets; Working With The User Presets; Saving User Presets - evertz 9590 Instruction Manual

Graticule generator, high definition graticule generator
Table of Contents

Advertisement

Models 9590 & HD9590 Graticule Generator Manual
Size
Either of the shaft encoders can be used to adjust the size of the circle around its centre, while
maintaining the selected aspect ratio for the H and V axes.
Position The left shaft encoder is used to adjust the vertical position of the circle, i.e. move the circle up
or down and the right shaft encoder is used to adjust the horizontal position of the circle, i.e.
move the circle left or right.

3.9. LOADING FACTORY PRESETS

The FACT PRESET button is used to recall the most recently used factory preset. Turn one of the shaft
encoder knobs to cycle through the available factory presets. The name of the selected preset will be
shown on the front panel display, and the selected collection of object settings will be loaded into to the
Graticule Generator. The PRESET ACTIVE LED will illuminate when one of the Factory presets is loaded.
The factory presets available at the time of printing are shown in Appendix B.
descriptions of the factory presets CA refers to clean aperture, AN refers to analog blanking aperture and
PA refers to production aperture.

3.10. WORKING WITH THE USER PRESETS

The Graticule Generator has ten memory locations to store user defined presets. Each preset contains a
collection of object parameters that define what objects are on, and the OBJECT MODES AND CTRL SEL
settings for the objects. There are ten user preset locations for each video standard. Each of the user
preset locations can be write-protected, or can left unlocked, so users can save their favourite settings.
When the Graticule Generator is first turned on, the ten user preset locations are filled with ten of the
factory presets.

3.10.1. Saving User Presets

To save the current object settings into one of the ten user preset memory locations, press the
PRESET SAVE button.
USER PRESET button corresponding to the location you wish to store the settings to. The Front panel
display will show SAVE to store n where n is the number of the user preset.
PRESET SAVE button a second time to confirm the operation (The Front panel display will show
Preset n stored) or press the ESC button to abort the store operation. If the user attempts to store a
preset into a write protected location the front panel will display the message Preset n locked.
User Presets cannot be deleted directly from memory they can only be
overwritten by another configuration saved to the same memory location.
Page 3-24
The Front panel display will show Store Preset #.
In the front panel
Then press the
RACK MOUNT PANEL OPERATION
Press the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd 9590

Table of Contents