Oki LP-1040 Maintenance Manual page 636

Wide format multifunction printer
Hide thumbs Also See for LP-1040:
Table of Contents

Advertisement

Color parameters
Number
ASC-107
ASC-108
ASC-109
ASC-110
ASC-111
ASC-112
ASC-113
ASC-114
ASC-115
ASC-116
Note:
The relationship between the adjustment value R (msec) and the number of lines N (dot) is
expressed below.
N (dot) = 60 (mm/sec) × [R (msec)/1000] × [600 (dpi) /25.4 (mm/inch) ]
If you want to shift the adjustment value N (dot), calculate how much you need to change
R (msec) with the following calculation.
R (msec) = 1000/60 (mm/sec) × [25.4 (mm/inch) /600 (dpi)] ×N (dot) = 25.4/36×N (dot)
*The calculation above is applied on the case that scan speed is 60 mm/sec.
11-38
Units
Range
msec
-
msec
-
msec
-
msec
-
msec
-
line
-
line
-
line
-
line
-
line
-
Default
Value
Specifies the time for the five A4 width CISs to start
scan at 240 mm/s for top scan edge adjustment.
374
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the time for the five A4 width CISs to start
scan at 225 mm/s for top scan edge adjustment.
399
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the time for the five A4 width CISs to start
scan at 150 mm/s for top scan edge adjustment.
598
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the time for the five A4 width CISs to start
scan at 60 mm/s for top scan edge adjustment.
1496
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the time for the five A4 width CISs to start
scan at 40 mm/s for top scan edge adjustment.
2244
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 240 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 225 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 150 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 60 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 40 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the