8.
Remove the screw on the outside of
STOPPER-PINCH-UNIT-L, which is located
on the left side of the scanner cover.
Loosen the screw on the inside.
9.
Use the screw you loosened on
STOPPER-PINCH-UNIT-L as a pivot point so
that you can rotate the scanner cover such
that it is open completely.
10.
Slowly tilt the scanner cover to the rear and
let go of it only when it stops moving any
further.
Notes
 Some of the photos below show the scanner
cover stopped upright, but when performing
these steps yourself, you need to lay the
scanner cover down completely.
 Be careful not to exert too much force on the
scanner cover or hit it with anything while
working.
11.
Pull upwards to remove the right ad left
plates:
- HOLDER-GLASS-L; and
- HOLDER-GLASS-R
that secure the scanner glass
(GLASS DOCUMENT).