9.17.2
GUIDE DC R MNT, GUIDE DC L MNT, DETACH NEEDLE
<Removal>
1.
Remove the one screw on each side of the
TRANSFER ROLLER UNIT and detach the
GUIDE (DC-R) (detach side) and ROLLER
(TRA-ASSY).
2.
Remove the set screw from the red high
voltage cable.
3.
Unscrew the five screws at the location
shown in the photo and remove the plate.
9-220
ROLLER(TRA-ASSY)
GUIDE(DC-R)