Door Latch Upper And Lower Cooking Chamber; Check Water Connection - Henny Penny FlexFusion ELECTRIC SPACESAVER PLUS TEAM Maintenance Manual

Hide thumbs Also See for FlexFusion ELECTRIC SPACESAVER PLUS TEAM:
Table of Contents

Advertisement

8.5.1 Door latch upper and lower cooking chamber

Check the function of the interlock
Test criteria
• Lock must be actuated (locking and unlocking).
If No
Change door latch.
Check the function of the interlock
Test criteria
• Locking plunger is undamaged and not worn.
If No
Replace locking block
Check the function of the interlock
Test criteria
• Locking plunger is firmly seated on the housing.
If no
Tighten the screw connection.

8.6 Check water connection

What type of water softening is present?
Test criteria
• Water filter available.
• Replacement date of the water filter?
• On-site water softening system available.
Checking the flexible conduit on the unit
Test criteria
• Flexible conduit is tight (no deposits or corrosion).
If No
Change flexible conduit.
Maintenance instructions
Performing maintenance
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsde 610

Table of Contents