Information for users changing from SIMOTION
D4x5-2
SIMATIC S7-1500 and the SIMOTION Motion Control system are two automation systems
whose architecture and therefore programming are fundamentally different. Be aware of
these differences when switching between the two automation systems.
Comparison
The comparison below is based largely on the hardware differences between a SIMATIC Drive
Controller and a SIMOTION D4x5-2 control unit.
Table A- 1
Differences between SIMOTION D4x5-2 control unit and SIMATIC Drive Controller
Feature
General
Size
(width x height x depth
)
Automation system
Available
Performance classes
Failsafe CPU
Integrated in the drive
Safety functions
Engineering
Controller
Drive
Device modeling
Runtime licenses (con-
trol)
Interfaces
Option slot
PROFINET interface 1
PROFINET interface 2
PROFINET interface 3
PROFINET interface 4
PROFIBUS interfaces
358
SIMOTION D4x5-2 DP/PN
Booksize
50 x 380 x 230 mm
SIMOTION
Four performance classes
(D425-2 / D435-2 / D445-2 / D455-2)
No
(additional SIMATIC S7 F-CPU required)
Yes, on the basis of SINAMICS S120
STEP 7 V5.x or TIA Portal with
SCOUT or SCOUT TIA
STARTER integrated in SCOUT
Controller and integrated automatic speed
control (SINAMICS Integrated) are modeled as
ONE device
With licensed memory card licenses: axis li-
censes, technology packages, etc.
Yes (for TB30 or CBE30-2)
PN IO with IRT: X150 (3 ports, 100 Mbps)
PN basic communication: X127 (1 port,
1000 Mbps)
PN basic communication: X130 (1 port,
1000 Mbps)
Optional, CBE30-2 (PN IO with IRT, 4 ports)
2 (master/slave)
SIMATIC Drive Controller
Booksize compact
50 x 300 x 226 mm
SIMATIC S7-1500
Two performance classes currently available
(CPU 1504D and CPU 1507D)
Yes
(TF-CPU)
Yes, on the basis of SINAMICS S120
TIA Portal with
STEP 7 Professional
Startdrive
Controller and integrated automatic speed con-
trol (SINAMICS Integrated) are modeled as TWO
devices in a TIA Portal group.
With engineering (STEP 7 Professional) licenses:
OPC UA, etc. (no axis licenses required with
SIMATIC)
No
PN IO with IRT: X150 (3 ports, 100 Mbps)
PN IO with RT: X160 (1 port, 100 Mbps)
PN basic communication: X130 (1 port,
1000 Mbps)
-
1 (master)
Note: PROFIBUS cannot be operated in isochro-
nous mode at the same time as other bus sys-
tems on MC Servo.