To adjust parameters:
1.
Go to the Pulse view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter for adjustment by pressing the control knob button (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob button (1).
Adjustable parameters:
Parameter
Pulse mode
Average current
Pulse frequency
Non-adjustable parameters:
Parameter
Pulse ratio
Pulse base current
Pulse current
These values depend also on other pulse parameters. The maximum pulse current is also limited by the machine spe-
cifications.
"Welding processes and features" on page 45
3.2.5 Settings view
In the Settings view, the selections are made with the control knob (1):
© Kemppi
Value
OFF/ON
Min = Current limit min, Max = Machine-specific
0.2 Hz ... 10 Hz, 0.1 Hz step
10 Hz ... 300 Hz, 1 Hz step
(Default = 2.5 Hz)
Value
40%
70%
Adjusted automatically
29
Master 315
Operating manual - EN
Note
When OFF is
selected,
pulse settings
are not visible.
When ON is
selected,
pulse settings
are visible and
adjustable.
These values
depend also
on other
pulse para-
meters.
Maximum
average cur-
rent is also lim-
ited by the
machine spe-
cifications.
Note
1921530 / 2052