17. The power adapter cord, Kangaroo OMNI™ Feeding Set tubing, and Kangaroo OMNI™ Enteral Feeding Pump
accessories may cause a tripping hazard. Avoid leaving wires, cords, or tubing in a pathway where a person could
trip on them and sustain injury.
18. Kangaroo OMNI™ Enteral Feeding Pump is designed for use on a conventional IV pole. As with any medical device,
it is possible for the weight of Kangaroo OMNI™ Enteral Feeding Pump to cause the IV pole to tip over. This could
result in injury to a patient or operator. When attaching Kangaroo OMNI™ Enteral Feeding Pump to the IV pole, take
precautions to ensure the IV pole remains stable while in use. It is recommended to consider the influence of pets
and children when deciding where to place an IV pole. It is important to prevent children and pets from tipping the
IV pole, which could result in injury.
19. When attaching Kangaroo OMNI™ Enteral Feeding Pump to an IV pole, ensure the pole clamp is tightly secured to
the pole to prevent the pump from falling.
20. Ensure audio output is unobstructed during normal operation so as to allow clear recognition of alarms. Inability to
hear the alarms could pose a serious risk to the patient, since the operator may not hear an alarm.
21. Additional equipment connected to medical electrical equipment must comply with the respective IEC or ISO
standards (e.g. IEC 60950/IEC 62368) for data processing equipment. Furthermore all configurations shall comply
with the requirements for medical electrical systems (See IEC 60601-1-1 or Clause 16 of the 3rd Edition or IEC
60601-1, respectively). Anyone connecting additional equipment to medical electrical equipment configures
a medical system and is therefore responsible that the system complies with the requirements for medical
electrical systems. Local laws take priority over the above mentioned requirements. If in doubt, consult your local
representative or the technical service department.
22. Kangaroo OMNI™ Enteral Feeding Pump was designed to meet IEC 60601-1 safety standards. For clarification
purposes, the Kangaroo OMNI™ Feeding Set is considered an Applied Part and has been tested and
evaluated accordingly.
23. Kangaroo OMNI™ Enteral Feeding Pump is designed and tested to minimize the effects of uncontrolled
electromagnetic interference and other types of interference from external sources. Avoid use of other equipment
that may cause erratic operation or degradation in the performance of Kangaroo OMNI™ Enteral Feeding Pump.
Electromagnetic interference could make the display unreadable or prevent Kangaroo OMNI™ Enteral Feeding
Pump from being able to feed.
24. For service or for technical information, please contact Customer Service.
25. Avoid using accessories, detachable parts or materials with Kangaroo OMNI™ Enteral Feeding Pump that are
not recommended in this manual. Use only approved Kangaroo OMNI™ Enteral Feeding Pump accessories with
Kangaroo OMNI™ Enteral Feeding Pump. Failure to use approved accessories could result in either damage to
Kangaroo OMNI™ Enteral Feeding Pump or physical injury.
26. Use Kangaroo OMNI™ Enteral Feeding Pump only as directed in this user manual. Do not interconnect
Kangaroo OMNI™ Enteral Feeding Pump with other devices or modify the equipment in any way outside of the
recommendations in this manual. Failure to comply could result in incorrect delivery of enteral fluids to the
patient or could damage Kangaroo OMNI™ Enteral Feeding Pump.
27. Kangaroo OMNI™ Enteral Feeding Pump are not intended to be used in MRI environments or in the presence of
strong magnetic fields. Do not use Kangaroo OMNI™ Enteral Feeding Pump in any areas with strong magnetic
fields. Kangaroo OMNI™ Enteral Feeding Pump contain metal components which could cause unintended
movement. This unexpected movement could cause harm due to falling objects or collisions.
28. Always disconnect the power adapter before cleaning or servicing. Failure to do so could result in electric shock to
the user performing the cleaning function. In some cases, electric shock can be fatal.
29. Use only the supplied power adapter to charge your Kangaroo OMNI™ Enteral Feeding Pump.
30. Do not open Kangaroo OMNI™ Enteral Feeding Pump as there are no user-serviceable parts inside. Opening may
affect function of device and voids the warranty. Kangaroo OMNI™ Enteral Feeding Pump is equipped with tamper
protection. The pump may cease to function if opened.
31. The application of this device is not bound to nutrition solutions of certain manufacturers.