To Output Basic Waveform
DG2000 series can output basic waveforms (including Sine, Square, Ramp, Pulse,
and Noise) from one channel or from both two channels at the same time. At start-up,
the dual channels are configured to output a sine waveform with 1 kHz frequency
and 5 Vpp amplitude by default. Users can configure the instrument to output
various basic waveforms.
To Select Output Channel
At start-up, the instrument displays the CH1 parameter interface by default. You can
press Output1 or Output2 (also, you can tap the channel output configuration
status bar or
currently selected channel. The interface of CH1 channel is displayed in red, and that
of CH2 is displayed in blue.
After the desired channel is selected, you can configure the waveform and
parameters of the selected channel.
Key Points:
CH1 and CH2 cannot be both selected at the same time. You can first select CH1,
after configuring the waveform and parameters of CH1, then select CH2 for
configuration.
2-2
) to switch between CH1 and CH2 as the