Rigol DG2052 User Manual page 82

Function/arbitrary waveform generator
Hide thumbs Also See for DG2052:
Table of Contents

Advertisement

Chapter 2 Front Panel Operations
RIGOL
To Set Modulation Polarity
Tap the Polarity parameter selection field to select "Positive" or "Negative" polarity
of the modulating waveform to control the output phase.
In the internal modulation, set the polarity to "Positive", and the generator will
output the carrier phase when the modulating waveform amplitude is a logic low
level. It will output the modulating phase when the modulating waveform amplitude
is a logic high level. The situation is the opposite when the polarity is set to
"Negative".
In the external modulation, set the polarity to "Positive", and the generator will
output the carrier phase when the external input signal is a logic low level. It will
output the modulation phase when the external input signal is a logic high level. The
situation is the opposite when the polarity is set to "Negative".
2-52
DG2000 User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dg2000 seriesDg2072Dg2102

Table of Contents