Figure 6 Pin connections for an 8-way RJ45

Table 7 Active gauge connector pin-out

3.8 Electrical data

If the pumping system uses an E2M1.5, the motor start up current is drawn for less than
one second, so slow-blow fuses must be used to prevent unnecessary fuse failure when
the pump starts. If using the pump at temperatures lower than 12 °C (53.6 °F), the start
up current will be drawn for longer, this may cause the motor thermal overload device to
open.
Table 8 Electrical data
Supply voltage
D39595880_A
D39595880_A - Technical data
Function
Pin
1
Power supply positive
2
Power supply common
3
Signal input
4
Identification
5
Signal common
6
Control line 1
7
Control line 2
8
Not connected
50/60 Hz
100
120
200
230
100
120
200
230
Current (A)
Full load
XDD1 / nEXT300
3.5
2.9
1.75
1.52
E2M1.5 / nEXT300
5.1
4.25
2.55
2.22
Page 17
Power (W)
Start
-
-
-
-
13.6
12.0
6.4
5.7
10/2020 - ©Edwards Limited
350
350
350
350
510
510
510
510