Figure 2 Performance characteristics
1. Speed
1. Speed
Note:
XDS100B is not suitable for prolonged operation at inlet pressures above 20 mbar. Under
such conditions, the inverter may reduce the motor speed.
The above performance curve shows the XDS100B Scroll Booster speed and power
consumption when used in conjunction with a XDS35i backing pump.
3.4 Mechanical data
Table 3 General mechanical data
Overall dimensions (L x W x H)
Maximum tilt angle
Nominal rotational speed
Mass
Inlet connection
Outlet connection
Degree of protection (IEC60529)
3.5 Electrical data
Table 4 Electrical data
Supply (V)
200 ‑ 230
100 ‑ 120
A73201880_G
A73201880_G - Technical data
Phase
Single
Single
Page 13
2. Power
2. Power
476 x 333 x 396 mm
10 degrees
1750 rpm
48 kg
NW40
NW40
IP44
Frequency (Hz)
50 - 60
50 - 60
05/2022 - ©Edwards Limited
Current (A)
6.6