2.3

Electrical data

Description
Input supply voltage, 3-phase, a.c., rms
Input supply frequency
Input supply wiring configuration
Input supply branch circuit protection requirements
Input supply voltage un-balance
Input supply short-circuit rating
System Earthing
Second protective Earth (ground) conductor
Installation category
*
Typical Earth leakage
*
Typical Earth leakage values were measured at steady-state conditions.
Note that higher leakage currents may occur:
i) under transient conditions such as power on or pump acceleration or
ii) with certain supply configurations such as Earthed phase or
iii) with abnormal supply configurations such as a missing phase or unbalanced supply voltages
Contact Edwards for more information about configuration requirements for Earth leakage reduction.
Table 5 - Electrical ratings: ultimate vacuum and extracted (700 torr) exhaust load condition
Electrical sub-system: ultimate vacuum (0.01 mbar) load rating
Input supply
Input supply
voltage
frequency
(V) (a.c., rms)
(Hz)
200
50
200
60
240
50
240
60
380
50
380
60
460
50
460
60
*
The electrical sub-system ratings, detailed in
The displayed power consumption, in
consumption of the pump's internal auxiliary power-supply. This auxiliary power-supply is used to power the
pump's motor-controller, pump-controller and customer accessories.
© Edwards Limited 2010. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Table 4 - General electrical data
Voltage un-balance should NOT exceed 2%, when
Must be fitted with a cross-sectional area at least
Input supply current
(A)
(A) (a.c., rms)
(Repetitive
Peak)
4.0
16.2
3.9
15.2
3.3
13.6
3.2
12.9
2.2
9.0
2.1
8.8
1.8
7.7
1.8
7.5
Table
5, assume an input short-circuit rating of 30 kA.
Table
5, is a typical value and does NOT include the power
Rating
200 - 460 ±10%
50 - 60 ±5 Hz
3 wire plus Earth (ground)
Refer to
Table 8
assessed over any one minute period.
30 (absolute maximum rating)
200 - 240 V: TT; TN and IT
(including corner-Earth supplies)
380 - 460 V: TT; TN and IT
(excluding corner-Earth supplies)
equal to the phase conductor size.
Over-voltage category II (IEC 60664-1)
<3.5
*
Input supply
Displayed power / motor
power
(kW)
0.55
0.55
0.55
0.55
0.55
0.55
0.55
0.55
A541-11-880 Issue A
Units
V
Hz
%
kA
mA
power
(kW)
0.52
0.52
0.52
0.52
0.52
0.52
0.52
0.52
Page 7