The XDS35iE is suitable for regular, rapid pumping of small chambers or for evacuation of large volumes with no
maximum chamber limit.
2.3

Mechanical data

2.3.1

General

Overall dimensions (L x W x H)
Maximum tilt angle
Nominal rotational speed
Mass
Inlet connection
Outlet connection
Degree of protection (IEC60529)
2.4

Electrical data

Pumps are supplied set to 200 - 230 V
Supply (V)
200 - 230
100 - 120
Area
UK
Europe
US
Japan
© Edwards Limited 2018. All rights reserved.
Table 4 - Typical pump down times of XDS35iE
3
Chamber size [m
]
Pump down time [minutes]
1
3
10
30
Table 5 - General mechanical data
Table 6 - Electrical data
Phase
Single
Single
Table 7 - Recommended regional supply protection
Voltage
230 V
230 V
120 V
100 V
14.5
43.3
144.3
432.7
476 x 333 x 396 mm
Frequency (Hz)
50/60
50/60
A730-01-880 Issue L
10 degrees
1750 rpm
48 kg
NW40
NW25
IP44
Current (A)
6.6
10.6
Rating
13 A
16 A
15 A
15 A