Honeywell Fire-Lite Alarms ES-1000X Manual page 61

Addressable fire alarm control panel
Table of Contents

Advertisement

Master Programming Level
1=STANDARD ADJECTIVE
2=STANDARD NOUN
3=CUSTOM ADJECTIVE
4=CUSTOM NOUN
Adjective/Noun Screen
1=BASEMENT
2=BOILER RM
3=CLASSROOM
Noun Screen #1
1=KITCHEN
2=LOBBY
3=OFFICE
Noun Screen #5
Pressing 3 or 4 while viewing the Adjective/Noun Screen will display screens similar to the previous Adjective and Noun Screens. The new
screens will list Custom Adjectives and Nouns which have been programmed into the control panel using the FS-Tools utility.
Description
EDIT MONITOR
1=ADJECTIVE/NOUN
2=DESCRIPTION
Edit Monitor Screen #5
A flashing cursor will appear at the first asterisk to the left. The programmer can enter additional descriptive information about the device
being programmed. This information will appear on the LCD display along with the standard device label information.
A maximum of 20 characters (including spaces) can be entered. To enter alphanumeric characters from the keypad, repeatedly press the
appropriate key until the desired character is displayed in the first position. For example, to enter the letter B, press the 2 (ABC) key three
times to toggle through the characters 2, A and B. Press the right arrow key to move the cursor one position to the right and repeat the process
to enter the next character. To enter a space, press the * (QZ) key four times until a blank appears in the desired position. When all characters
have been entered, press the Enter key to store the information. The display will return to the Edit Monitor Screen #4, displaying the new
information at the bottom of the screen.
Edit Module Screen for Control Modules
MODULES
1=ADD
2=DELETE
3=EDIT
Modules Screen
A flashing cursor will appear in the position of the first asterisk to the left.
The programmer keys in the three digit module address, such as 002. When the last digit is keyed-in, if the selected address corresponds to a
control module, a screen displaying information about the control module with the selected address will be displayed as illustrated in the fol-
lowing:
In the preceding example:
Normal - indicates that the module with the selected address is physically installed on the SLC and communicating with the control
panel (enabled)
<ADJ><NOUN> - represents the adjective and noun, which have been programmed, describing the location of the displayed device
Control - indicates that the selected module is a control module
X or * - represents Wireless (X) or Wired (*)
S or * - represents Silenceable (S) or Nonsilenceable (*)
ES-1000X Series Manual — P/N LS10133-000FL-E:A 6/21/2023
Pressing 2 while viewing the Adjective/Noun Screen will cause the following screen(s) to be displayed. Note
that the keypad down arrow key must be pressed to see all the Noun screens. Press the number corresponding to
the noun that is to be used as a descriptor for the location of the monitor module currently being programmed.
1=CLOSET
2=CORRIDOR
3=ELECTRIC RM
Noun Screen #2
1=PATIENT
2=RESTROOM
3=ROOM
Noun Screen #6
The Description selection allows the programmer to enter additional information about the monitor module cur-
rently being programmed. This information will be displayed as part of the device label on the LCD display.
Pressing 2 while viewing Edit Monitor Screen #5 will cause the following screen to be displayed:
DESCRIPTION
ADJECTIVE/NOUN
Adjective/Noun Screen
The programmer can change a module's existing or factory default programming by pressing 3 in the Modules
Screen. The following screen will be displayed:
EDIT MODULE
ENTER MODULE ADDRESS
Edit Module Screen
Normal CONTROL
Edit Control Screen #1
1=ELEVATOR
2=ENTRANCE
3=FLOOR
Noun Screen #3
1=STAIRWAY
2=STOREROOM
3=WING
Noun Screen #7
1M012
<ADJ><NOUN>
ZNNN
SW 1M002
Programming
1=GARAGE
2=HALLWAY
3=HVAC RM
Noun Screen #4
1=ZONE
Noun Screen #8
61