The tables on the following pages list all of the Events and their default Event Codes for the various Communication Formats.
The information shown in Table 3.3 is automatically programmed for the Central Station phone number Event Codes when the Ademco
Contact ID or SIA Format is selected. Enter 0s for an Event Code Setting to disable the report. Disabled reports will not get called to the
Central Station. The programmer may enable the Event Types in programming as described on the previous page.
Event Description
PULL STATION
MON-USER-DEF-1
WATERFLOW
MON-USER-DEF-2
SMOKE (PHOTO)
DET-USER-DEF-1
SMOKE (ION)
DET-USER-DEF-2
HEAT DETECTOR
DET-USER-DEF-3
HIGH HEAT
USER DEF 15
SMOKE DUCT-P
DET-USER-DEF-4
PHOTO W/HEAT
DET-USER-DEF-5
CO ALARM
DET-USER-DEF-6
PHOTO SUPERISORY
USER DEF 14
DUCT SUPERVISORY
DET-USER-DEF-7
PHOTO SUPER AR
DET-USER-DEF-8
CO SUPERVISORY
DET-USER-DEF-9
PHOTO ADAPT
DET-USER-DEF-10
PHOTO BEAM
DET-USER-DEF-11
MONITOR
MON-USER-DEF-3
SMOKE CONVEN
MON-USER-DEF-5
HEAT CONVENTIONAL
MON-USER-DEF-6
MEDIC ALERT
MON-USER-DEF-7
HAZARD ALERT
MON-USER-DEF-8
TORNADO ALRT
MON-USER-DEF-9
TAMPER
MON-USER-DEF-11
MON SUPERVISORY
84
Ademco Contact ID
Active
Zone
115
Zone
115
Zone
113
Zone
113
Zone
111
Zone
111
Zone
111
Zone
111
Zone
114
Zone
114
Zone
114
Zone
114
Zone
116
Zone
116
Zone
111
Zone
111
Zone
162
Zone
200
Zone
200
Zone
200
Zone
200
Zone
200
Zone
200
Zone
111
Zone
200
Zone
111
Zone
111
Zone
111
Zone
111
Zone
111
Zone
110
Zone
110
Zone
111
Zone
111
Zone
114
Zone
114
Zone
100
Zone
100
Zone
150
Zone
150
Zone
150
Zone
150
Zone
144
Zone
144
Zone
200
Zone
Table 3.3 Event Codes
ES-1000X Series Manual — P/N LS10133-000FL-E:A 6/21/2023
Active
Point
Point
FA
Point
FA
Point
SA
Point
SA
Point
FA
Point
FA
Point
FA
Point
FA
Point
KA
Point
KA
Point
KA
Point
KA
Point
FA
Point
FA
Point
FA
Point
FA
Point
GA
Point
FS
Point
FS
Point
FS
Point
FS
Point
FS
Point
FS
Point
FA
Point
GS
Point
FA
Point
FA
Point
FA
Point
FA
Point
FA
Point
FA
Point
FA
Point
FA
Point
FA
Point
KA
Point
KA
Point
MA
Point
MA
Point
PA
Point
PA
Point
PA
Point
PA
Point
TA
Point
TA
Point
FS
Master Programming Level
SIA
Restoral
FH
FH
SH
SH
FH
FH
FH
FH
KH
KH
KH
KH
FH
FH
FH
FH
GH
FV
FV
FV
FV
FV
FV
FH
GV
FH
FH
FH
FH
FH
FH
FH
FH
FH
KH
KH
MH
MH
PH
PH
PH
PH
TH
TH
FV

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fire-lite alarms es-1000xcFire-lite alarms es-1000xi

Table of Contents