Monitor serial port changes

You can choose to monitor CTS and/or DCD changes on the serial port.
1.
Log in to the Connect IT web
2. Click Configuration in the left pane.
Digi Connect IT® 4 User Guide
Description
The number of data bits for the serial port. This value must
match the data bits configuration for the equipment
connected to the Connect IT.
The default is 8.
The type of parity bit for the serial port. This value must match
the parity bit configuration for the equipment connected to
the Connect IT.
The default selection is NONE.
The number of stop bits for the serial port. This value must
match the stop bits configuration for the equipment
connected to the Connect IT.
The default is 1.
The type of flow control for the serial port. This value must
match the flow control configuration for the equipment
connected to the Connect IT.
The default selection is NONE.
The sequence of characters used to start an escape sequence.
Escape sequences allow a user to send control commands to
the serial port interface. These commands are removed from
the data stream and are not sent to the equipment connected
to the serial port.
If left blank, the escape sequence is disabled.
The default is a tilde (~).
An entry is optional.
The number of bytes from the serial port which should be
buffered. The buffered bytes are redisplayed when a user
connects to the serial port.
The minimum value is 0.
The default is 4000.
Select this option if access to the serial port should be limited
to a single active section. If not selected, multiple active
sessions are available on the port.
The length of time after which the active session is
disconnected after a period of user inactivity.
Syntax: number{w|d|h|m|s}
A setting of 0 disables idle timeouts.
The default is 15m.
UI.
Configure a serial port
35