Configure the Connect IT Mini
Setting
Data bits
Parity
Stop bits
Flow control
5. Click Save or Apply.
Monitor serial port changes
You can choose to monitor CTS and/or DCD changes on the serial port.
1.
Log in
to manage the Connect IT.
2.
Access the Configuration > Serial
3. Expand the port that you want to configure.
4. Expand the Monitor section.
5. Configure the settings.
Setting
CTS
DCD
6. Click Save or Apply..
Enable a Telnet connection on the serial port
You can enable a Telnet connection on the serial port.
1.
Log in
to manage the Connect IT.
2.
Access the Configuration > Serial
Digi Connect IT® Mini User Guide
Description
The number of data bits for the serial port. This value must
match the data bits configuration for the equipment
connected to the Connect IT.
The default is 8.
The type of parity bit for the serial port. This value must match
the parity bit configuration for the equipment connected to
the Connect IT.
The default selection is NONE.
The number of stop bits for the serial port. This value must
match the stop bits configuration for the equipment
connected to the Connect IT.
The default is 1.
The type of flow control for the serial port. This value must
match the flow control configuration for the equipment
connected to the Connect IT.
The default selection is NONE.
screen.
Description
Select the CTS option to monitor CTS changes on this port.
Select the DCD option to monitor DCD changes on this port.
screen.
Configure a serial port
25