Zones - Quick Review; Loop Devices - Settings - Teletek electronics iRIS8 User Operation & Maintenance Manual

Addressable fire alarm control panel
Hide thumbs Also See for iRIS8:
Table of Contents

Advertisement

4.1.2. Zones – Quick Review
Next to ZONES menu is situated button << GRID VIEW for quick reviewing the operation status of all zones. The zones
are reviewed at several screens, as 60 numbers are displayed at the same time.
First are displayed the zone numbers from 1 to 60.
The Enabled zone numbers are presented with active
button in blue. The Disabled zone numbers are presented
with active button in white.
For quick access to a zone setting menu, press its
number. To go back from zone menu to grid view menu,
press EXIT button.
To exit from the << GRID VIEW menu press EXIT button.
4.1.3. Loop Devices – Settings
At Access Level 2, the user can perform the following actions with loop devices:
- Review the device's current system status, name, set address and loop number;
- Change the operation status of the device Enabled/Disabled;
- Add new found device in the system;
- Fix the type of a device in the system.
Enter SYSTEM – PROGRAMMING - DEVICES – menu.
Enter LOOP menu. Common settings are available for the different loop devices. The loop devices are presented with a
system name and additional name description (if set from engineer).
Note: You can directly enter the address/loop number
using the virtual keyboard after selecting the digit button in
the middle – fields 5 and 6.
The address number must be in range from 1 to 250.
The loop number must be in range from 1 to 8.
iRIS8 - Addressable Fire Alarm Panel – User & Maintenance Manual
To review the zone numbers from 61 to 120, press down
arrow button. Press button again to review zones from
121 to 180, etc. Press the up arrow button to move back.
Every change of the operation status of the zones is
updated immediately in the Grid View menu.
Quick summery for the submenus:
- Settings for Loop Devices
- Quick review of the loop devices' status (by
address number)
Fields description:
(1) Device System Name – Inactive text field with the
system name of the device according its type. See all
devices SensoIRIS series described in
(2) Device Operation Status – Active button for
changing operation status of the device.
(3) Device System Status – Inactive text field with
the current operation status of the device.
(4) Device Name - Inactive field with the set name for
the device. The name is set at Access Level 3 from
engineer.
(5) Address – Use the arrow buttons to review the
devices set to next/previous address.
(6) Loop Number - Use the arrow buttons to change
the loop number and to review the devices.
21