Jump starting (24V)

1
Turn the ignition and all power consuming equipment
off. Switch off the engine on the machine which is
providing jump start power.
Jump leads must have 24V.
24V
First connect the jump start battery's positive terminal
(1) to the flat battery's positive terminal (2).Then
connect the jump start battery's negative terminal (3)
to, for example, a bolt (4) or the lifjting eye on the
machine with the flat battery.
4
Start the engine on the power providing machine. Let it
run for a while. Now try to start the other machine.
Disconnect the cables in the reverse order.
4812158701_G.pdf
Special instructions
Dispose of old batteries in an environmentally
Dispose of old batteries in an environmentally
friendly way. Batteries contain toxic lead.
friendly way. Batteries contain toxic lead.
Do not use a quick-charger for charging the
Do not use a quick-charger for charging the
battery. This may shorten battery life.
battery. This may shorten battery life.
Do not connect the negative cable to the
Do not connect the negative cable to the
negative terminal on the dead battery. A spark
negative terminal on the dead battery. A spark
can ignite the oxy-hydrogen gas formed
can ignite the oxy-hydrogen gas formed
around the battery.
around the battery.
Check that the battery used for jump starting
Check that the battery used for jump starting
has the same voltage as the dead battery.
has the same voltage as the dead battery.